CISA keeps a public list of security flaws that attackers are known to be using. On November 25, 2026 it added 10 entries from four unrelated products. CISA does not link the four vendors to one campaign. Five entries are in the conferencing component of Mitel MiCollab, a business phone and collaboration system. Mitel says the file-upload flaw (CVE-2026-133275) could let an unauthenticated attacker upload files because the file type is not checked properly. Mitel's advisory also says another flaw could let an attacker run commands on the system. One entry is a Juniper Session Smart Conductor flaw (CVE-2026-103406). It could let attackers run commands with root (full administrator) privileges. One is a Xen Orchestra login bypass (CVE-2026-133469). Vates says it uses a crafted cookie to act as an administrator. Three are older flaws in Danfoss AK-SM 800A refrigeration controllers. Danfoss fixed these in earlier firmware, but CISA now says they are being exploited. Most of these products are business or industrial equipment, so ordinary home users are unlikely to be running them.
On November 25, 2026, CISA added 10 vulnerabilities to its list of flaws known to be used in real attacks. They affect Mitel MiCollab, Juniper Session Smart Conductor/Router, Vates Xen Orchestra and Danfoss AK-SM 800A refrigeration controllers. Fixes exist for all of them, so anyone running these products should check their version and update.
Who is affected
- Mitel MiCollab: <cite index="12-7">version 10.3 (10.3.0.18) and earlier</cite> (conferencing component, called AWV).
- Juniper Session Smart Conductor: <cite index="39-6">versions before 7.0.5, 7.1.0 up to before 7.1.7, and 7.2.0 up to before 7.2.3.</cite> CISA's entry also names Session Smart Router, and the fixed releases are the same.
- Vates Xen Orchestra and Xen Orchestra Appliance: <cite index="43-3">versions before 6.9.2 (stable channel) or 6.10.1 (latest channel).</cite>
- Danfoss AK-SM 800A Series: per public reporting, firmware older than 3.3 (CVE-2023-25914 and CVE-2023-25915) and older than R4.2 (CVE-2025-41450). <cite index="51-3">CISA's 2025 advisory confirms the R4.2 detail for CVE-2025-41450.</cite> I could not confirm the 3.3 detail from Danfoss itself.
Is it being exploited?
CISA added the 10 vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog on November 25, 2026, based on evidence of active exploitation. For Juniper, the vendor said at least one malicious exploitation had been reported to its security team. For Xen Orchestra, Vates said the flaw was actively exploited by a threat actor when it published its advisory on November 10, 2026. CISA's alert gives no attack details for the Mitel and Danfoss entries. Whether ransomware gangs are using any of them is not confirmed. The score shown (9.8) is the highest one I could confirm, for the Juniper flaw. Some press reports put the worst Mitel flaw at 10.0, but I could not confirm that from an official source.
What you should do now
Home users
- These are business and industrial products. Most households don't run them, and no action is needed if you don't.
- If you use a business phone or conferencing system provided by an employer or IT provider, ask them whether it is Mitel MiCollab and whether it has been updated.
- If you run a home lab with Xen Orchestra or XCP-ng, update Xen Orchestra to 6.9.2 (stable) or 6.10.1 (latest), and don't expose it directly to the internet.
Businesses
- Make a list of any Mitel MiCollab, Juniper Session Smart, Xen Orchestra or Danfoss AK-SM controllers you own, including ones managed by vendors or IT providers.
- Mitel MiCollab: apply the Mitel patch for release 10.3 (10.3.0.18), described in knowledge-base article KB000129195, or move to a later release. Until then, <cite index="6-8">restrict external access to the AWV component.</cite>
- Juniper: upgrade Session Smart Conductor and Router to 7.0.5, 7.1.7, 7.2.3 or later. <cite index="30-13">Juniper says there is no workaround for CVE-2026-103406.</cite>
- Xen Orchestra: upgrade to 6.9.2 or 6.10.1 or later. Move it off the public internet, onto a management network, VPN or approved-address list. <cite index="42-12">Vates notes the unauthenticated access leaves no log entry in Xen Orchestra,</cite> so look for signs of compromise using the indicators in Vates' advisory (VSA-2026-062). If you suspect a compromise, <cite index="42-11">rotate all passwo
- Danfoss AK-SM 800A: upgrade the firmware using Danfoss's software upgrade process, and keep controllers off direct internet exposure. Separately, <cite index="53-1">older Danfoss AK-SM 800 and AK-SC 355 models are end-of-life, so security patches may no longer be available.</cite> Isolate those units and plan to replace them.
- Because several of these flaws were exploited before or soon after their patches came out, patching alone may not be enough. Have your IT provider check for signs of intrusion, such as unexpected files, new accounts or unusual outbound traffic, especially on internet-facing MiCollab and Xen Orchestra servers.
How to check if you're affected
- Mitel MiCollab: sign in to the MiCollab administration page and check the installed version and patch level. Compare it with Mitel advisory MISA-2026-0012. Versions 10.3 (10.3.0.18) and earlier need the patch.
- Juniper Session Smart: on the Conductor or Router, check the software version (for example with the show system version command, or the version shown in the web interface). Compare it with 7.0.5, 7.1.7 and 7.2.3.
- Xen Orchestra: the version appears in the web interface, in the About or Settings area. Appliance (XOA) users can also run the update tool. Check that it shows 6.9.2 (stable) or 6.10.1 (latest) or newer.
- Danfoss AK-SM 800A: the firmware version is shown in the controller's web interface. Compare it with the fixed versions in the 'Fixed versions' list. Ask your refrigeration or facilities contractor if you aren't sure.
- Not sure which of these you use? Ask your IT provider for an inventory of internet-facing systems.
Fixed versions and workarounds
- Mitel MiCollab (CVE-2026-133275, -133303, -133311, -133323, -133324): Patch for release 10.3 (10.3.0.18) (KB000129195), or a later release
- Juniper Session Smart Conductor / Router (CVE-2026-103406): 7.0.5, 7.1.7 or 7.2.3 (or later)
- Vates Xen Orchestra (CVE-2026-133469): 6.9.2 (stable) or 6.10.1 (latest), or later
- Danfoss AK-SM 800A (CVE-2025-41450): Release R4.2 or later
- Danfoss AK-SM 800A (CVE-2023-25914, CVE-2023-25915): Firmware 3.3 or later, per public reporting. I could not confirm this from Danfoss itself.
Until you can update:
- Mitel: until the patch is applied, limit outside access to the MiCollab conferencing (AWV) component.
- Juniper: Juniper says there is no workaround, so upgrade.
- Xen Orchestra: if you can't update right away, take it off the internet and put it behind a VPN or management network, as Vates advises.
- Danfoss: keep controllers off the public internet and on a separate, restricted network.
About this advisory
Researched with AI help from public sources and checked against the official advisories listed with this alert. Details can change; follow your vendor's guidance.
Security news feeds we follow
Get every BIS alert in your news reader: Technology Alerts RSS. Follow the same sources we watch: download all of them as one file (OPML) and import it into any feed reader.
- CISA Cybersecurity Advisories
- CISA Known Exploited Vulnerabilities
- CISA News
- Cisco Security Advisories
- Fortinet PSIRT (FortiGuard)
- Google Chrome Releases
- Google Security Blog
- Microsoft Security Update Guide (MSRC)
- BleepingComputer
- Forbes Innovation (shown on biscomputer.com/news)
- Krebs on Security
- Microsoft Security Blog
- SecurityWeek
- The Hacker News
Questions? Contact BIS Computer Solutions, Inc.
5500 Alta Canyada Rd., La Canada, CA 91011 USA · Phone: +1-818-248-5023 · Fax: +1-818-249-1169 · Email: support@biscomputer.com · Web: www.biscomputer.com
What you need to do
Make a list of any Mitel MiCollab, Juniper Session Smart, Xen Orchestra or Danfoss AK-SM controllers you own, including ones managed by vendors or IT providers.
Is this a hack?
Yes, confirmed CISA added the 10 vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog on November 25, 2026, based on evidence of active exploitation. For Juniper, the vendor said at least one malicious exploitation had been reported to its security team. For Xen Orchestra, Vates said the flaw was actively exploited by a threat actor when it published its advisory on November 10, 2026. CISA's alert gives no attack details for the Mitel and Danfoss entries. Whether ransomware gangs are using any of them is not confirmed. The score shown (9.8) is the highest one I could confirm, for the Juniper flaw. Some press reports put the worst Mitel flaw at 10.0, but I could not confirm that from an official source.